Manufacturer ModelNo Watts (w) Efficiency (%) Voc (V)Isc (A)Vmp (V)Imp (A)Tolerance
(%)
Weight (kg) Weight (lbs)
HelioSphera HS-130 130 9.09 130.01.42102.71.3 5.0~0.0 25.0 55.1
Inventux Technologies AG X 130 130 9.09 131.01.45105.01.2 -3.0~3.0 25.0 55.1
Kaneka Corporation U-EA110 110 9.02 71.02.5054.02.0 -5.0~10.0 18.0 39.7
Sharp NA-953WQ 95 9.01 65.32.3048.02.0 -10.0~10.0 18.0 39.7
Sharp NA-F128(G5) 128 9.00 59.83.4545.42.8 10.0~-5.0 19.0 41.9
Sharp NA-F128(H5) 238 9.00 238.00.85186.00.7 19.0 41.9
Bauer Solarenergie GmbH BS-130-MA10 128 8.94 134.31.58105.81.2 -5.0~5.0 26.0 57.3
HelioSphera HS-125 125 8.74 130.01.42102.71.2 5.0~0.0 25.0 55.1
Inventux Technologies AG X 125 125 8.74 130.01.42103.01.2 -3.0~3.0 25.0 55.1
Pramac SWISS S.A. MCPH 125 125 8.67 134.01.50105.01.2 -5.0~5.0 25.5 56.2
Kaneka Corporation U-EA105 105 8.61 71.02.4053.52.0 -5.0~10.0 18.0 39.7
Bauer Solarenergie GmbH BS-125-MA10 123 8.57 134.21.56105.41.2 -5.0~5.0 26.0 57.3
Phönix Solar AG PHX-90 90 8.53 62.22.1149.31.8 -10.0~10.0 18.0 39.7
Sharp NA-901WP 90 8.53 65.22.1149.31.8 -10.0~10.0 18.0 39.7
Sharp NA-902WP 90 8.53 65.22.1149.31.8 -10.0~10.0 18.0 39.7
Sharp NA-F121(A5) 121 8.50 238.00.67180.00.7 19.0 41.9
Sharp NA-F121(G5) 121 8.50 59.23.3545.02.7 10.0~-5.0 19.0 41.9
Sharp NA-F121(H5) 121 8.50 238.00.83180.00.7 19.0 41.9
HelioSphera HS-120 120 8.39 130.01.42102.71.2 5.0~0.0 25.0 55.1
Chint Solar (Astronergy) CHSM5001T-120 120 8.39 133.11.5394.41.3 -5.0~5.0 25.5 56.2
Inventux Technologies AG X 120 120 8.39 129.01.38101.01.2 -3.0~3.0 25.0 55.1
NexPower Technology NT-130AX 130 8.25 76.82.7259.02.2 -5.0~5.0 20.5 45.2
SPS Solar GmbH SPS 130 130 8.24 131.01.44101.01.3 -5.0~10.0 22.0 48.5
Auria Solar M 120000 118 8.22 130.51.37105.01.1 -5.0~5.0 25.0 55.1
Bauer Solarenergie GmbH BS-120-MA10 118 8.22 134.01.53105.01.1 -5.0~5.0 26.0 57.3
Kaneka Corporation U-EA100 100 8.20 71.02.2553.51.9 18.3 40.3
Sontor GmbH SN2-145 145 8.15 128.81.71104.61.4 -5.0~5.0 37.0 81.6
Sharp NA-F115(G5) 115 8.10 58.63.2644.52.6 10.0~-5.0 19.0 41.9
Sharp NA-F115(H5) 115 8.10 238.00.81174.00.7 19.0 41.9
Sharp NA-F115(A5) 115 8.10 238.00.81174.00.7 19.0 41.9
Please note that these pages are meant strictly for informational purposes to those seeking retailers/wholesalers/manufacturers/providers of or information about renewable energy products and/or services. Inclusion or exclusion from these pages does not imply a recommendation or lack thereof by Posharp and/or its collaborator(s) for any particular company or organization. The information are collected from the Internet or input by companies.